Fire risk assessment types 1–4 explained (and when you need an intrusive one)

Fire risk assessment types for blocks of flats are usually described as Type 1, 2, 3 or 4, depending on whether they cover the flats as well as the common parts, and whether anything is opened up. Here's what each type involves and when you need more than the standard Type 1.

Updated 3 min read London Fire Safety Consultants

In short

  • Type 1 – common parts, non-destructive – is the normal standard for most blocks.
  • Type 2 adds destructive inspection of the common parts. Type 3 adds non-destructive inspection of some flats.
  • Type 4 – common parts and flats, destructive – is reserved for serious concerns.
  • There's no fixed legal review frequency, but assessments must be kept under review and recorded in full.

Where the four types come from

The four types were set out in the Local Government Association's guide Fire safety in purpose-built blocks of flats, and are now widely used by assessors and managing agents. BS 9792:2025, the current code of practice for housing fire risk assessment, gives clearer treatment of the different types.

Fire risk assessment types at a glance

Type Area covered Inspection Typical use
Type 1 Common parts only Non-destructive The standard FRA for most blocks
Type 2 Common parts only Destructive (sampled) Concerns about compartmentation or construction in the common parts
Type 3 Common parts and some flats Non-destructive Questions about stay put, flat entrance doors or separation between flats
Type 4 Common parts and some flats Destructive (sampled) Serious concerns about construction, often after a fire or major defect

Type 1: the standard FRA

A Type 1 assessment covers the common parts – entrances, corridors, stairs, plant rooms, bin stores – without opening up the structure. It considers what can be seen: fire doors, signage, emergency lighting, detection, housekeeping, management arrangements and the information given to residents. It's what the Fire Safety Order requires for most blocks, but it can only assume that hidden construction, such as compartment walls above ceilings, is adequate.

Type 2: destructive inspection of common parts

A Type 2 assessment adds intrusive inspection of the common parts – for example lifting ceiling tiles, opening service risers or making small openings – to check compartmentation and fire-stopping. It usually needs a contractor to open up and make good. Many clients now commission a dedicated compartmentation survey instead.

Type 3: common parts and flats, non-destructive

A Type 3 assessment includes access to a sample of flats, looking at flat entrance doors, the protected entrance hall, detection in the flats and any obvious breaches of separation. It's appropriate where a stay put strategy depends on each flat being a fire-resisting compartment and there's reason to doubt it – for example in conversions, or where flats have been altered.

Type 4: common parts and flats, destructive

A Type 4 assessment combines Type 3 access with destructive inspection inside flats. It's disruptive, expensive and only appropriate where there are serious concerns – for example after a fire has shown unexpected spread, or where major construction defects are suspected.

Which type do you need?

  • Start with Type 1 for most purpose-built blocks.
  • Escalate where the Type 1 identifies concerns it can't resolve – unexplained assumptions about compartmentation, or doubts about stay put.
  • Consider a retrospective fire strategy alongside, so the assessor knows how the building is supposed to work – see fire strategy vs fire risk assessment.

How often should a fire risk assessment be reviewed?

The law doesn't set a fixed frequency. The responsible person must keep the assessment under review and update it if there's reason to think it's no longer valid, or after significant changes. Many managing agents review larger blocks annually, with full reassessment periodically, and more often for higher-risk buildings. Since 1 October 2023, the full assessment must be recorded in writing, including who carried it out.

Choosing the right type: examples

  • A purpose-built 1990s block with good records and no concerns: a Type 1 is normally enough.
  • A block where the Type 1 found unsealed holes in the riser cupboards: a compartmentation survey or Type 2 to check the common parts more thoroughly.
  • A converted Victorian building operating stay put: a Type 3 to check flat entrance doors and separation inside a sample of flats.
  • A block where a recent fire spread unexpectedly between flats: a Type 4, alongside specialist advice.

Our fire risk assessments cover all four types, and we'll recommend the right one for your building.

Sources

This guide is general information based on the law and guidance in England as at 8 November 2026. It isn't legal advice – for advice on a specific building, get in touch.

FAQs

Frequently asked questions

What is a Type 1 fire risk assessment?

A non-destructive assessment of the common parts of a block of flats. It's the normal standard for most purpose-built blocks.

When do I need a Type 3 fire risk assessment?

When there's reason to doubt that each flat acts as a fire-resisting compartment – for example in converted buildings or where flats have been altered – especially if the building relies on a stay put strategy.

Is a Type 4 fire risk assessment ever routine?

No. Type 4 involves destructive inspection inside flats and is reserved for serious concerns, such as after a fire or where major construction defects are suspected.

How often should a fire risk assessment be done for flats?

There's no fixed legal frequency. It must be kept under review and updated after significant changes. Many managing agents review larger blocks annually, and higher-risk buildings more often.

Talk to a specialist

Not sure which FRA type you need?

Tell us about the building and any concerns – we'll recommend the right type and a fixed fee.

  • Reply within one working day
  • Qualified specialist for your building
  • Fixed-fee proposal before you commit

Prefer to talk? Call 020 8058 1692 – Mon–Fri 8:30am–5:30pm.

Request a proposal

Reply in 1 working day

Tell us about the building – we'll confirm what's needed and come back with a fixed-fee proposal.

We'll only use your details to respond to this enquiry and, where needed, share them with the specialist assigned to your project – see our privacy policy.

Prefer to talk? 020 8058 1692

Call Get a proposal