Fire strategies, FRAEWs and Building Safety Act support – London, Berkshire and UK-wide

Guide · Fire risk assessments & compliance

BS 8674:2025 explained: fire risk assessor competence levels and risk profiles

BS 8674:2025 is the first British Standard to define fire risk assessor competence. Instead of a single "competent or not" test, it sets three levels – foundation, intermediate and advanced – matched to the fire risk profile of the building. Here's what BS 8674 says, how the risk profiles work, and how building owners and managing agents can use it to appoint the right assessor.

Updated 5 min read London Fire Safety Consultants

In short

  • BS 8674:2025 was published by BSI on 15 August 2025.
  • It sets three competence levels: foundation, intermediate and advanced.
  • The assessor's level should match the building's fire risk profile – low, moderate or high.
  • It's a code of practice, not law – but certification schemes and the planned regulation of assessors are being built around it.

What is BS 8674:2025?

BS 8674:2025 – Built environment: Framework for competence of individual fire risk assessors – Code of practice was published by the British Standards Institution on 15 August 2025. It sets out the skills, knowledge, experience and behaviours an individual needs to carry out fire risk assessments in occupied buildings.

It deals with the person, not the method. The method for carrying out an assessment is covered by other standards – for housing, BS 9792:2025, which replaced PAS 79-2. BS 8674 also aligns with BS 8670-1:2024, the core criteria for building safety competence frameworks.

Why BS 8674 was needed

The Regulatory Reform (Fire Safety) Order 2005 says a responsible person must make a "suitable and sufficient" fire risk assessment, and that anyone helping them must be "competent". It doesn't define competence or require any qualification. In practice, that meant:

  • Anyone could call themselves a fire risk assessor
  • A short course could be presented as enough for any building
  • Building owners had no simple way to compare assessors

The Grenfell Tower Inquiry recommended mandatory accreditation of fire risk assessors, and the government has accepted it. BS 8674 gives the industry a common yardstick for that – see mandatory fire risk assessor certification.

The three BS 8674 competence levels

Level Typical premises What the assessor should be able to do
Foundation Simple, low-risk buildings with low occupancy – such as a small office or shop Assess straightforward premises with standard fire precautions, and recognise when something is beyond them
Intermediate Buildings of moderate complexity and broader use – such as public venues and many mid-rise residential blocks Work independently on mixed-use and multi-occupied buildings with more involved fire safety systems
Advanced High-risk or complex buildings – such as large residential blocks, care homes, hospitals and premises with vulnerable occupants Assess complex evacuation strategies, engineered fire safety measures and buildings where failure has severe consequences

The examples above are typical, not a fixed list. Two buildings of the same type can sit at different levels depending on their height, layout, occupants and fire safety systems.

What are BS 8674 fire risk profiles?

BS 8674 links each competence level to a fire risk profile for the premises – low, moderate or high. These terms aren't new, but BS 8674 uses them to answer one question: is this assessor competent for this building? They're not the same as the overall risk rating at the end of a fire risk assessment.

Factors that push a building into a higher fire risk profile include:

  • Height and the number of storeys – especially buildings over 11 metres, and higher-risk buildings of 18 metres or 7 storeys and above
  • Sleeping risk – flats, hotels, student accommodation, care homes
  • Vulnerable occupants – people who may need help to evacuate (see residential PEEPs)
  • A single staircase or complex escape routes
  • The evacuation strategy – stay put, simultaneous or phased
  • Engineered fire safety measures – smoke control, sprinklers, fire-fighting lifts, a fire strategy based on fire engineering
  • Mixed uses – shops, car parks or plant below flats
  • Concerns about the external walls or compartmentation

The core principle: don't exceed your competence

BS 8674 is clear that competence isn't "qualified or not qualified". A competent assessor:

  • Only takes on buildings within their level
  • Recognises the limits of a fire risk assessment – for example, it isn't an FRAEW or an intrusive survey
  • Recommends specialist input where needed, such as a fire engineer, external wall assessor or fire door inspector
  • Keeps their knowledge current through CPD
  • Behaves ethically, including declaring conflicts of interest

BS 8674 doesn't name specific courses. But certification schemes are now mapping to it. For example, the BAFE SP205 scheme for fire risk assessment companies has updated its qualification requirements to reference BS 8674, with regulated qualifications broadly mapped as:

  • Foundation – typically a Level 3 qualification
  • Intermediate – typically a Level 4 qualification
  • Advanced – typically a Level 5 qualification or higher, plus substantial experience

A qualification alone doesn't make someone competent for a building. BS 8674 expects qualifications, experience of similar buildings and ongoing CPD together.

No. BS 8674 is a code of practice. The legal duty is still a suitable and sufficient fire risk assessment by a competent person. But it's quickly becoming the benchmark:

  • The government's 2026 consultation on regulating fire risk assessors proposed a tiered competency framework based on BS 8674
  • Certification bodies are using it to set assessor levels
  • Insurers, lenders and fire and rescue services are likely to ask whether your assessor was competent for the building

If something goes wrong, being able to show you appointed an assessor at the right BS 8674 level is strong evidence that you took your duty seriously.

How to use BS 8674 when appointing a fire risk assessor

  1. Work out your building's risk profile. Consider height, occupants, evacuation strategy, mixed uses and any known issues.
  2. Ask which BS 8674 level the assessor works at, and how that's evidenced.
  3. Check third-party certification – for example, a UKAS-accredited scheme such as BAFE SP205 – or a professional register such as those run by the IFE or IFSM.
  4. Ask about experience with your building type and height, and for an anonymised sample report.
  5. Check the method – for housing, ask whether the assessment follows BS 9792:2025.
  6. Ask how they escalate issues outside a fire risk assessment, such as external walls or fire strategy questions.
  7. Record who you appointed. Since 1 October 2023, responsible persons have had to record the name of anyone who carries out or reviews their fire risk assessment.

What this means for blocks of flats

Most blocks of flats over 11 metres – and every higher-risk building – are likely to need an assessor at the intermediate or advanced level. Buildings with a stay-put strategy, a single stair, residents who need help to evacuate, or historic compartmentation or cladding concerns should be assessed at the advanced level.

Our fire risk assessments are carried out by certificated assessors matched to the building's risk profile, with fire engineers on hand where a building needs more than a standard assessment.

How we can help

We match each project to a qualified specialist and confirm the scope, the named professional and a fixed fee before you commit.

Sources

This guide is general information based on the law and guidance in England as at 21 November 2026. It isn't legal advice – for advice on a specific building, get in touch.

FAQs

Frequently asked questions

What is BS 8674?

BS 8674:2025 is a British Standard code of practice that sets out a framework for the competence of individual fire risk assessors. It defines three levels – foundation, intermediate and advanced – matched to the risk and complexity of the building.

When was BS 8674 published?

BSI published BS 8674:2025 on 15 August 2025.

Is BS 8674 mandatory?

No. It's a code of practice, not law. But the government's proposals for regulating fire risk assessors refer to a tiered framework based on BS 8674, and certification schemes are aligning with it.

What level of fire risk assessor do I need for a block of flats?

It depends on the building's risk profile. Many mid-rise blocks need at least an intermediate-level assessor. Taller and higher-risk buildings, and those with a stay-put strategy, single stair or vulnerable residents, should be assessed at the advanced level.

What is the difference between BS 8674 and BS 9792?

BS 8674 covers the competence of the person carrying out a fire risk assessment. BS 9792 covers how a fire risk assessment of housing should be carried out and recorded.

Talk to a specialist

Need an assessor at the right BS 8674 level?

Tell us about the building – we'll match it to a certificated assessor and confirm a fixed fee.

  • Reply within one working day
  • Qualified specialist for your building
  • Fixed-fee proposal before you commit

Prefer to talk? Call 020 8058 1692 – Mon–Fri 8:30am–5:30pm.

Request a proposal

Reply in 1 working day

Tell us about the building – we'll confirm what's needed and come back with a fixed-fee proposal.

We'll only use your details to respond to this enquiry and, where needed, share them with the specialist assigned to your project – see our privacy policy.

Prefer to talk? 020 8058 1692

Call Get a proposal